INSTALLATION
9
MIN. 18” MAX 30”
net width
DUCT OPENING
CLEARANCES
Front
Rear
Front
Rear
Wall
Minimum clearance above range should be no
less than 18“ from the range surface to the
range hood’s base. Maximum height are
recommended not to exceed 30” for maximum
efficiency.
Net width on all models are call out width less
1/4”.
Note: Refer Manufacturers’ height clearance
requirements on all high btu and professional
ranges.
Call Out Size Net Width
30“ 29-3/4”
36“ 35-3/4”
42“ 41-3/4”
48“ 47-3/4”
Cut Out Size (A):
Hurricane 10-1/2“
Cyclone 10-1/2”
Whirlwind 8-1/2”
6”
7”
2-1/2”
(A)
4-1/2”3-1/4 x 10”
Wall
Vedere la pagina 10