USE, CARE, AND INSTALLATION GUIDE
Read all Instructions before Installing and operating this appliance
MODEL: ZTO-M79S
IMPORTANT SAFETY NOTICE
WARNING
Installation
The installation in this manual is intended for qualified installers, service technicians or persons
with similar qualified background. DO NOT attempt to install this appliance yourself. Injury
could result from installing the unit due to lack of appropriate electrical and technical
background.
All electrical wiring must be properly installed, insulated and grounded. Overly accumulated
grease in old duct work should be cleaned out or duct work should be replaced if necessary to
avoid the possibility of a grease fire. Check all joints on duct work to insure proper connection
and all joints should be properly taped.
Operations
Read all instructions in this manual before operating the appliance. Save these instructions for
future reference.
Always leave safety grills and filters in place. Without these components, operating blowers
could catch on to hair, fingers and loose clothing.
NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.
NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch
fire. The risk of self combustion is higher when the oil has been used several times.
Cleaning
The saturation of greasy residue in the blower and filters may cause increased inflammability.
Keep unit clean and free of grease and residue build-up at all times to prevent possible fires.
Filters must be cleaned periodically and free from accumulation of cooking residue (see
cleaning instructions inside). Old and worn filters must be replaced immediately. Do not
operated blowers when filters are removed. Never disassemble parts to clean without proper
instructions. Disassembly is recommended to be performed by qualified personnel only. Call
our service center for removal instructions.
The manufacturer declines all responsibility in the event of failure to observe the
instructions given here for installation, maintenance and suitable use of the product.
The manufacturer further declines all responsibility for injury due to negligence and the
warranty of the unit automatically expires due to improper maintenance.
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - IMPORTANT SAFETY NOTICE

USE, CARE, AND INSTALLATION GUIDERead all Instructions before Installing and operating this applianceMODEL: ZTO-M79SIMPORTANT SAFETY NOTICEWARNINGInst

Pagina 2 - CONTENTS

Blower On/OffBy pressing , the blower is switched On and Off. When switched on, the blower starts up on speed level 3. Speed Selecti

Pagina 3 - INSTALLATION

FEATURES & CONTROLSCONTROLS: FILTER CHANGE INDICATOR (Carbon Filters)Filter Change Reminder (Carbon, if fitted): When your hood is installed as a

Pagina 4

FEATURES & CONTROLSCONTROLS: FILTER CLEAN INDICATOR (Metal Filters)Filter Clean Reminder (Standard Metal Filters fitted)Whether your hood is insta

Pagina 5

MAINTENANCECLEANINGSurface Maintenance:,Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e

Pagina 6

MAINTENANCELIGHTS,Make sure all power is turned off and bulbs are not hot.,Carefully pry trim (w/ glass) off the socket module.,Replacement bulb w/ 12

Pagina 7

WARRANTYTO OBTAIN SERVICE UNDER WARRANTY:You must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales

Pagina 8

TO OBTAIN SERVICE UNDER WARRANTYor any Service Related Questions, please call:1-888-880-8368Have your product proof of purchase with date ready for wa

Pagina 9

CONTENTSINSTALLATIONMount heights & clearanceDuctingSpecificationsElectricalMounting the hoodEZ AnchorsDuctless ConversionCarbon Filters11,2,3445,

Pagina 10 - FEATURES & CONTROLS

A minimum of 6" round or 3-1/4 x 10" rectangular duct must be used to maintain maximum air flow efficiency.Always use rigid type metal ducts

Pagina 11

INSTALLATION2DUCTING,,NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must

Pagina 12

INSTALLATIONDUCTING6" to 3-1/4 x 10" elbowadaptor.Air Diverting KitAir registerDuctless Re-circulating optionDuctless Re-circulating optionC

Pagina 13 - MAINTENANCE

INSTALLATIONSPECIFICATIONSELECTRICALCable LockWARNING: All Electrical work must by performed by qualified electrician or person with similar technica

Pagina 14

Mounting the Range Hood1. Mark hood center on Center hood on wall.2. Mark and Install Wall Mount Bracket to Wall. (For hollow drywall, use E-Z Ancho

Pagina 15 - WARRANTY

INSTALLATIONINSTALLATIONEZ ANCHORSTap EZ anchor tip into marked drywall locations, turn with screwdriver until seated flush.Note: Whenever possible, t

Pagina 16 - 1-888-880-8368

Carbon Filters (Required)1. Purchase ductless Charcoal Filters as follow:2. Remove metal filters on hood. Clip carbon filters onto